Transient modeling of a D-type boiler with natural circulation loop: a study on boiler performance during a step change in load

Document Type : Original Article

Authors

1 Department of Mechanical Engineering, Najafabad Branch, Islamic Azad University, Najafabad, Iran

2 هیات علمی دانشگاه آزاد اسلامی واحد نجف آباد

3 Department of Mechanical Engineering, Najafabad Branch, Islamic Azad University, Najafabad, Iran.

Abstract

In this paper, the dynamic modeling of a D-type boiler was performed during a step increase in loading. The D-type boilers are used in industry to produce process saturated steam. In these types of boilers, heat absorption occurs in two sections of the furnace and the convection section. The pipes of the convection section are indirectly exposed to heat, causes the flow direction to change from the upper drum to lower drum and vice versa. One of the special features of this boiler is that the drum circulation loop is natural and as a result, the hydraulic balance equations of the system must be considered. In the present modeling, the equations of water-side were considered in one-dimensional and the equations of flue gas-side were considered in three-dimensional space using the zonal method. The transient continuity and energy equations of the water-side form a system of nonlinear ordinary differential equations which were solved using the Runge–Kutta method. To solve the water and gas-side equations in two-way coupling method, a Fortran computer program has been developed. Investigation of the boiler operating parameters during start-up can help to improve the existing control system. The comparison of the present results with the test data of the desired boiler showed that maximum modelling errors are equal to 4.8, 1, and 6.8 percent for steam pressure, drum water temperature, and outlet steam of boiler during start-up, respectively. Also, the boiler response to a step increase in consumer steam demand is less than 20 seconds.
.

Keywords

Main Subjects


[1] M. Hashemi Beni, S. Emami, A. H. Meghdadi Isfahani, A. Shirneshan and R. Kalbasi, “Transient simulation and exergy analysis of a D-type steam boiler with natural circulation during cold start: A case study,” Applied Thermal Engineering, Vol. 210, 2022, 118367.
[2] E. Rosado-Tamariz, M. A. Zuniga-Garcia and R. Batres, “Optimization of a drum boiler startup using dynamic simulation and a micro-genetic algorithm,” Energy Reports, Vol. 6, 2020, pp. 410-416.
[3] Y. Zhao, M. Liu, C. Wang, Z. Wang, D. Chong and J. Yan, “Exergy analysis of the regulating measures of operational flexibility in supercritical coal-fired power plants during transient processes,” Applied Energy, Vol. 253, 2019, 113487.
[4] C. Fan , Z. Cui, J. Wang , Z. Liu and W. Tian, “Exergy analysis and dynamic control of chemical looping combustion for power generation system,” Energy Conversion and Management, Vol. 228, 2021, 113728.
[5] G. Ahmadi, D. Toghraie, O. Akbari, “Energy, exergy and environmental (3E) analysis of the existing CHP system in a petrochemical plant,” Renewable and Sustainable Energy Reviews, Vol. 99, 2019, pp. 234-242.
[6] O. Mahdavi Keshavar, A. Jafarian and M. Sohrabi Shekafti, “Dynamic simulation of a heat recovery steam generator dedicated to a brine concentration plant,” Journal of Thermal Analysis and Calorimetry, Vol. 135, 2019, pp. 1763-1773.
[7] R. D. Bell and K. J. Åström, “A fourth order non-linear model for drum boiler dynamics,” IFAC Proceedings Volumes, Vol. 29, 1996, pp. 6873-6878.
[8] H. E. Emara-Shabaik, M. A. Habib and I. Al-Zaharna, “Prediction of risers’ tubes temperature in water tube boilers,” Applied Mathematical Modelling, Vol. 33, 2009, pp. 1323-1336.
[9] J. Pan, D. Yang, H. Yu, Q. C. Bi, H. Y. Hua, F. Gao and Z. M. Yang, “Mathematical modeling and thermal-hydraulic analysis of vertical water wall in an ultra supercritical boiler,” Applied Thermal Engineering, Vol. 29, 2009, pp. 2500-2507.
[10] J. Pan, D. Yang, G. Chen, X. Zhou and Q. Bi, “Thermal-hydraulic analysis of a 600 MW supercritical CFB boiler with low mass flux,” Applied Thermal Engineering, Vol. 32, 2012, pp. 41-48.
[11] F. Alobaid, J. Ströhle, B. Epple and H. G. Kim, “Dynamic simulation of a supercritical once-through heat recovery steam generator during load changes and start-up procedures,” Applied Energy, Vol. 86, 2009,  pp. 1274-1282.
[12] A. Sedić, S. Katulić and D. Pavkovic, “Dynamic model of a natural water circulation boiler suitable for on-line monitoring of fossil/alternative fuel plants,” Energy Conversion and Management, Vol. 87, 2014,  pp. 1248-1260.
[13] Z. Shu, L. Zixue, D. Yanxiang and Z. Huaichun, “Development of a distributed-parameter model for the evaporation system in a supercritical W-shaped boiler,” Applied Thermal Engineering, Vol. 62, 2014, pp. 123-132.
[14] N. Mertens, F. Alobaid, R. Starkloff, B. Epple and H. G. Kim, “Comparative investigation of drum-type and once-through heat recovery steam generator during start-up,” Applied Energy, Vol. 144, 2015, pp. 250-260.
[15] X. Zhu, W. Wang and W. Xu, “A study of the hydrodynamic characteristics of a vertical water wall in a 2953t/h ultra-supercritical pressure boiler,” International Journal of Heat and Mass Transfer, Vol. 86, 2015, pp. 404-414.
[16] J. Z. Liu, S. Yan, D. L. Zeng, Y. Hu and Y. Lv, “A dynamic model used for controller design of a coal fired once-through boiler-turbine unit,” Energy, Vol. 93, 2015, pp. 2069-2078.
[17] C. Sreepradha, R. C. Panda and N. S. Bhuvaneswari, “Mathematical model for integrated coal fired thermal boiler using physical laws,” Energy, Vol. 118, 2017, pp. 985-998.
[18] D. Dave, W. Arnold, S. Timothy and M. Reed, “Dynamic simulation studies for boiler draft,” Applied Thermal Engineering, Vol. 121, 2017, pp. 255-293.
[19] K. Deng, C. Yang, H. Chen, N. Zhou and S. Huang, “Start-up and dynamic processes simulation of supercritical once-through boiler,” Applied Thermal Engineering, Vol. 115, 2017, pp. 937-946.
[20] K. G. Bilde, K. Sørensen and T. Condra, “Mathematical model of natural circulation biomass boilers during start-up,” International Journal of Heat and Mass Transfer, Vol. 143, 2019, 118477.
[21] Y. Niu, M. Du, W. Ge, H. Luo and G. Zhou, “A dynamic nonlinear model for a once-through boiler-turbine unit in low load,” Applied Thermal Engineering, Vol. 161, 2019, 113880.
[22] T. Guoli, Z. Man, G. Junping, W. Yuxin, Y. Hairui, Z. Yanjun, W. Guohua and L. Junfu, “Thermal-hydraulic calculation and analysis on evaporator system of a 660 MWe ultra-supercritical CFB boiler,” Applied Thermal Engineering, Vol. 151, 2019, pp. 385-393.
[23] M. Trojan, “Modeling of a steam boiler operation using the boiler nonlinear mathematical model,” Energy, Vol. 175, 2019, pp. 1194-1208.
[24] J. Taler, W. Zima, P. Ocłoń, S. Grądziel, D. Taler, A. Cebula, M. Jaremkiewicz, A. Korzeń, P. Cisek, K. Kaczmarski and K. Majewski, “Mathematical model of a supercritical power boiler for simulating rapid changes in boiler thermal loading,” Energy, Vol. 175, 2019, pp. 580-592.
[25] H. Hajebzadeh, A. N. M. Ansari and S. Niazi, “Mathematical modeling and validation of a 320MW tangentially fired boiler: A case study,” Applied Thermal Engineering, Vol. 146, 2019, pp. 232-242.
[26] S. Grądziel and K. Majewski, “Simulation of heat transfer in combustion chamber waterwall tubes of supercritical steam boilers,” Chemical and Process Engineering, Vol. 37, 2016, pp. 199-213.
[27] S. Grądziel, “Analysis of thermal and flow phenomena in natural circulation boiler evaporator,” Energy, Vol. 172, 2019, pp. 881-891.
[28] H. Fan, Z. G. Su. P. H. Wang and K.Y. Lee, “A dynamic nonlinear model for a wide-load range operation of ultra-supercritical once-through boiler-turbine units,” Energy, Vol. 226, 2021, 120425.
[29] F. M. White, Fluid Mechanics, 7th Edition, New York, McGraw Hill, 2011.
[30] D. G. Kröger, Air-cooled heat exchangers and cooling towers: thermal-flow performance evaluation and design, Vol. 2, Oklahoma, Pennwell Corporation, 2004.
[31] J. R. S. Thom, “Prediction of pressure drop during forced circulation boiling of water,” International Journal of Heat and Mass Transfer, Vol. 7, 1964, pp. 709-724.
[32] W. Rohsenow, J. Hartnett and Y. Cho, Handbook of Heat Transfer, New York, McGraw Hill, 1998.
[33] D. G. Kröger, Air-cooled heat exchangers and cooling towers: thermal-flow performance evaluation and design, Vol. 1, Oklahoma, Pennwell Corporation, 2004.
[34] J. G. Collier and J. R. Thome, Convective Boiling and condensation, Third edition, New York, Oxford University Press, 1994.